1-123
3000 to 3099
3005: The MicroKernel router encountered an operating
system error
The MicroKernel router encountered an unexpected error from the
operating system, such as a shared memory failure. Check the
Pervasive Event Log (PVSW.LOG) for more information.
3006: The MicroKernel router detected an invalid session
The session information contained in a position block is invalid.
This status code occurs for one of the following reasons:
The application is trying to use a position block for a file that
resides on an engine and for which the connection has been
previously terminated via a B_STOP (25) or B_RESET (28)
operation.
The application is trying to use a position block for a file that
resides on a remote server and that encountered an abnormal
network error on a previous operation.
When using only the NetBIOS protocol with a remote
Workgroup engine, the client is sending more bytes than can fit
into the engine’s network read buffer. Go the machine where the
remote Workgroup engine is installed, and try increasing the
value of the configuration parameter, Server
Communication
Buffer Size
Read Buffer Size.
3008: Invalid configuration for MicroKernel router
This status code results from an invalid configuration. For example,
if both client configuration options, Access
Use Local MicroKernel
Engine and Access
Use Remote MicroKernel Engine are set to Off,
the router has no valid path to take. If this situation occurs, set at
least one of these options to On, depending on whether you are using
a local engine, a remote Server engine, or both.
3009: NETinterface.DLL is not loaded
The MicroKernel router could not find NETAPI.DLL.
3012: Local engine is not accessible to the MicroKernel
router
Access to the local engine is not possible because it is not loaded or
could not be launched. You can receive this status code if you try to
Komentáře k této Příručce